Who the checklist is for
This checklist is for engineering, security and product teams that build or run software holding electronic protected health information (ePHI) for US healthcare customers. Most of these teams are business associates: SaaS vendors, development partners, hosting and support providers. Covered entities building their own software can use it too.
It turns the HIPAA Security Rule into checks an engineer can confirm or a reviewer can ask to see. It also covers the Privacy Rule and Breach Notification Rule duties that land on software teams. It doesn't replace legal advice or a formal risk analysis. Use it to find the gaps.
How to use it
- Start with scope. If you can't list every system that holds ePHI, the rest of the checklist will miss things. Logs, backups, analytics and support tools are where PHI often hides.
- Tick only what you can prove. For each item, ask what evidence you would show a hospital's security reviewer: a policy, a screenshot, a ticket, a log extract. If there's nothing to show, leave it unticked.
- Turn gaps into risk register entries. Every unticked item should become a risk with an owner and a date.
- Repeat yearly and whenever you add a vendor, a data flow or a major feature.
Your ticks stay in this browser, so you can come back and finish later.
How the Security Rule is organised
The Security Rule sits in 45 CFR Part 164, Subpart C. It has three groups of safeguards:
- Administrative safeguards (164.308): risk analysis and risk management, a named security official, workforce security, access management, training, a sanctions policy, incident procedures, a contingency plan with backups and disaster recovery, regular evaluation, and BAAs with vendors.
- Physical safeguards (164.310): facility access, workstation use and security, and device and media controls, including disposal and reuse.
- Technical safeguards (164.312): access control with unique user IDs, emergency access, automatic logoff and encryption; audit controls; integrity; person or entity authentication; and transmission security.
Some specifications are marked required and others addressable. Addressable means you must implement the control or document why it isn't reasonable and what you do instead. Encryption is addressable in the current rule. In practice, not encrypting ePHI is very hard to justify, and encrypted data that meets HHS guidance falls outside the definition of unsecured PHI for breach purposes.
All of this must be written down. Section 164.316 requires you to keep Security Rule policies, procedures and records of required actions and assessments for 6 years from creation or the date they were last in effect, whichever is later.
The proposed update, and what has changed
On 6 January 2025 HHS published a proposed rule to strengthen the Security Rule. It would remove most of the addressable category, require encryption and MFA, a technology asset inventory and network map, vulnerability scans every six months, yearly penetration tests, restoring critical systems within 72 hours, and yearly verification of business associates' safeguards. As of November 2026 this is still a proposal. The current text of 164.308 to 164.316 is unchanged, so don't describe these as legal requirements. Several hints in the checklist point to them because enterprise customers already ask for most of them.
A separate change is final. On 19 November 2026 HHS published a Privacy Rule final rule. From 19 July 2027, covered entities must answer patients' access requests within 15 calendar days, down from 30, with one extension of up to 30 days. If your product holds the records, you need to be able to export them quickly.
Common gaps
- A risk analysis that is really a policy template. It must name your systems, your threats and your risks. A generic document that could belong to any company doesn't meet the requirement.
- PHI in the wrong tools. Error trackers, session replay, product analytics and log platforms collect request bodies and screen contents. Each one needs a BAA or scrubbing.
- A cloud BAA with non-eligible services. AWS, Azure and Google Cloud sign BAAs for their HIPAA-eligible services only. Check each service in the PHI path.
- AI features added without a BAA. Sending clinical text to a model API is a disclosure to a business associate. See using LLMs with patient data.
- Production data in test environments. Use synthetic or de-identified data, and keep developers away from real PHI.
- No proof of review. Audit logs that nobody reads, and access reviews with no record, don't count as controls.
What to do next
Sign the right agreements first. Our business associate agreement template covers both the customer BAA and a subcontractor BAA for your own vendors. Then use the incident response plan template to build the breach process the checklist asks for. If customers also ask for SOC 2, the SOC 2 readiness checklist overlaps with much of this work.
Our HIPAA development guide explains the cloud architecture behind many of these items. We build HIPAA-ready environments for MedTech products through our cloud and infrastructure team. If a hospital security review is coming up, let's get you ready.